System board and components
16.6.4 Replacing the microSD card
16.6.4.1 Preliminary steps
Ê
"Locating the defective server" on page 47
Ê
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
"Getting access to the component" on page 52
Ê
"Removing the air duct" on page 73
16.6.4.2 Replacing the microSD card
Ê
Remove the Dual microSD 64GB Enterprise, see section
Dual microSD 64GB Enterprise" on page 394
Ê
Remove the defective microSD card from the Dual microSD 64GB
Enterprise. Proceed as described in the following:
Ê
To eject the defective microSD card, gently push it in and then let go (see
).
Ê
Pull the microSD card straight out of its slot.
V
CAUTION!
The microSD card contains customer information. After replacing the
microSD card, hand the defective card over to the customer. If the
customer requests disposal of the defective microSD card, proceed
as follows:
Ê
Using a pair of side-cutting pliers, cut the microSD card in half.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
a pair of side-cutting pliers
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...