116
Upgrade and Maintenance Manual
RX2530 M4
Power supply unit (PSU)
6.2.1.4
Concluding steps
Ê
"Connecting the power cord" on page 63
Ê
If applicable, configure the redundant power supply.
6.2.2 Removing a hot-plug PSU
I
The procedure of removing an AC PSU or a DC PSU differs only in
disconnecting/connecting the power cord.
I
If a hot-plug PSU should be removed from a redundant configuration,
while the system is in operation, proceed the following:
Ê
Disconnect the power cord from the dedicated PSU, see section
"Disconnecting the power cord" on page 50
.
A CSS error is detected and the message "redundancy lost" is
displayed using the iRMC web interface. Your configuration is now
non-redundant. The CSS error is only an information. After removing
the PSU out of its bay, the CSS error will be cleared automatically.
6.2.2.1
Preliminary steps
Ê
Only when replacing a PSU in a non-redundant configuration:
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver (for DC PSU -48 V)
Summary of Contents for PRIMERGY RX2530 M4
Page 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Page 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Page 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Page 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Page 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Page 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Page 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Page 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Page 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Page 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...