Remove the riser module 1, see
"Removing a riser module" on page 69
Replacing the microSD card
▶
Remove the Dual microSD 64GB Enterprise, see
microSD 64GB Enterprise" on page 377
.
▶
Remove the defective microSD card from the Dual microSD 64GB
Enterprise.
Proceed as described in the following:
▶
To eject the defective microSD card, gently push it in and then let go.
▶
Pull the microSD card straight out of its slot.
▶
Install the new microSD card on the Dual microSD 64GB Enterprise.
Proceed as described in the following:
▶
With the label facing up, insert the microSD card into the microSD slot on
the controller until it locks in place.
▶
Install the Dual microSD 64GB Enterprise, see
Concluding steps
▶
Install the riser module 1, see
"Installing a riser module" on page 69
.
▶
▶
"Connecting the power cord" on page 62
▶
"Switching on the server" on page 66
▶
"Installing the front cover with lock" on page 66
.