17.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with CPU heat
sink
installed in CPU slot CPU 1
1 memory module
installed in DIMM slot 1A
Common Operation
Panel (COP)
1 PSU
installed in PSU bay PSU 1
Table 3: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 4: Minimum startup configuration - cables
▶
"Shutting down the server" on page 48
.
▶
"Disconnecting the power cord" on page 49
.
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 62
▶
Connect a display to the server.
▶
Switch on the server, see
"Switching on the server" on page 66
Appendix A
RX2530 M6
Upgrade and Maintenance Manual
425
Summary of Contents for PRIMERGY RX2530 M5
Page 18: ...Content Upgrade and Maintenance Manual RX2530 M6 ...
Page 194: ...Fans 194 Upgrade and Maintenance Manual RX2530 M6 ...
Page 262: ...Expansion cards and backup units 262 Upgrade and Maintenance Manual RX2530 M6 ...
Page 278: ...Main memory 278 Upgrade and Maintenance Manual RX2530 M6 ...
Page 324: ...Accessible drives 324 Upgrade and Maintenance Manual RX2530 M6 ...
Page 336: ...Front panel 336 Upgrade and Maintenance Manual RX2530 M6 ...
Page 344: ...Serial interface 344 Upgrade and Maintenance Manual RX2530 M6 ...
Page 480: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...