Resetting the boot retry counter in the BIOS
▶
Enter the BIOS.
▶
Select the
Management
menu.
▶
Under
Boot Retry Counter
press the [+] or [-] keys to specify the maximum
number of boot attempts (0 to 7).
▶
Exit the BIOS.
Resetting the boot retry counter using the ServerView Operations
Manager
▶
In the ServerView Operations Manager
Administration
view, select
Server
Configuration
.
▶
If more than one server is managed in SVOM, select the target server and
click
Next
.
▶
From the
Server Configuration
menu pane, choose
Restart Options
.
▶
Under
Reboot Retries
, specify the maximum number of boot attempts (0 to
7) in the
Default for reboot tries
field.
Resetting the boot retry counter using iRMC S5 web interface
▶
Log in to the iRMC S5 web interface.
▶
Select the
Settings
menu.
▶
Select the
Server Management
menu.
▶
The following boot retry counter settings are available under
Automatic
System Recovery & Restart (ASR&R)
:
▶
Under
Retry counter max
specify the maximum number of attempts to
boot the OS (0 to 7).
▶
Under
Retry counter
the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
▶
Click
Apply
for the changes to take effect.
Basic software procedures
86
Upgrade and Maintenance Manual
RX2530 M6
Summary of Contents for PRIMERGY RX2530 M5
Page 18: ...Content Upgrade and Maintenance Manual RX2530 M6 ...
Page 194: ...Fans 194 Upgrade and Maintenance Manual RX2530 M6 ...
Page 262: ...Expansion cards and backup units 262 Upgrade and Maintenance Manual RX2530 M6 ...
Page 278: ...Main memory 278 Upgrade and Maintenance Manual RX2530 M6 ...
Page 324: ...Accessible drives 324 Upgrade and Maintenance Manual RX2530 M6 ...
Page 336: ...Front panel 336 Upgrade and Maintenance Manual RX2530 M6 ...
Page 344: ...Serial interface 344 Upgrade and Maintenance Manual RX2530 M6 ...
Page 480: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...