After replacing a network controller or the system board, switch on and boot
the server, see
"Switching on the server" on page 66
The hardware configuration tool for Red Hat Linux, will launch at boot and
detect the new and/or changed hardware on your system.
▶
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
If the system board or network controller offers multiple LAN ports, it
is necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
▶
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.3.11
Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see
"Suspending BitLocker functionality" on page 75
to complete the service task.
▶
If applicable, ask the system administrator to enter the recovery key in order
to boot the OS.
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting
the server after the maintenance task. However, if BitLocker
functionality has not been suspended, Windows will enter recovery
mode and ask you to input recovery key for further booting.
▶
Ask the system administrator to enable the previously suspended BitLocker
protection on the system volume, using the
BitLocker Drive Encryption
control panel item:
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
Basic software procedures
RX2530 M6
Upgrade and Maintenance Manual
93
Summary of Contents for PRIMERGY RX2530 M5
Page 18: ...Content Upgrade and Maintenance Manual RX2530 M6 ...
Page 194: ...Fans 194 Upgrade and Maintenance Manual RX2530 M6 ...
Page 262: ...Expansion cards and backup units 262 Upgrade and Maintenance Manual RX2530 M6 ...
Page 278: ...Main memory 278 Upgrade and Maintenance Manual RX2530 M6 ...
Page 324: ...Accessible drives 324 Upgrade and Maintenance Manual RX2530 M6 ...
Page 336: ...Front panel 336 Upgrade and Maintenance Manual RX2530 M6 ...
Page 344: ...Serial interface 344 Upgrade and Maintenance Manual RX2530 M6 ...
Page 480: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...