160
Upgrade and Maintenance Manual
RX2540 M2
Hard disk drives (HDD) and solid state drives (SSD)
7.3
Replacing 3.5-inch HDD/SSD SAS/SATA
backplanes
7.3.1
Replacing the 4x 3.5-inch HDD SAS backplanes
7.3.1.1
Preliminary steps
Ê
"Locating the defective server" on page 61
Ê
"Suspending BitLocker functionality" on page 95
Ê
"Shutting down the server" on page 65
Ê
"Disconnecting the power cord" on page 66
Ê
Remove all HDD/SSD modules from the server as described in section
"Removing 3.5-inch HDD modules" on page 150
.
V
CAUTION!
Ensure that all HDDs are uniquely identified so that you can reinsert
them into their original bays after replacing the HDD backplane.
Ê
"Getting access to the component" on page 68
Ê
"Removing the fan box" on page 397
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PZ2 / (+) No. 2 screw driver / nut driver 5 mm