170
Upgrade and Maintenance Manual
RX2540 M2
Hard disk drives (HDD) and solid state drives (SSD)
7.3.2
Upgrading SAS/SATA HDD backplane 2
7.3.2.1
Preliminary steps
Ê
"Locating the defective server" on page 61
Ê
"Suspending BitLocker functionality" on page 95
Ê
"Shutting down the server" on page 65
Ê
"Disconnecting the power cord" on page 66
Ê
"Getting access to the component" on page 68
Ê
"Removing the fan box" on page 397
7.3.2.2
Installing the 3.5-inch HDD backplane 2
Ê
"Installing the 4x 3.5-inch HDD SAS backplane 2" on page 167
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
flat screw driver
Phillips PZ2 / (+) No. 2 screw driver / nut driver 5 mm
Summary of Contents for PRIMERGY RX2540 M2
Page 6: ...Upgrade and Maintenance Manual RX2540 M2 ...
Page 48: ...48 Upgrade and Maintenance Manual RX2540 M2 Before you start ...
Page 128: ...128 Upgrade and Maintenance Manual RX2540 M2 Basic software procedures ...
Page 142: ...142 Upgrade and Maintenance Manual RX2540 M2 Power supply unit PSU ...
Page 392: ...392 Upgrade and Maintenance Manual RX2540 M2 Processor CPU ...
Page 452: ...452 Upgrade and Maintenance Manual RX2540 M2 Accessible drives ...
Page 558: ...558 Upgrade and Maintenance Manual RX2540 M2 System board and components ...
Page 602: ...602 Upgrade and Maintenance Manual RX2540 M2 Appendix ...