308
Upgrade and Maintenance Manual
RX2540 M2
Expansion cards and backup units
8.6.4.4
Removing the air grid extension from riser module 2 (FL)
Figure 205: Removing the air grid extension from riser module 2
Ê
Remove the two screws (see circles).
Ê
Remove the air grid extension in the direction of the arrow.
8.6.4.5
Removing a GPGPU card
Ê
Remove the GPGPU card as described in section
8.6.4.6
Installing the slot cover riser module 2
Ê
Install the slot cover as described in section
"Installing the slot cover riser
8.6.4.7
Installing the rear air grid riser module 2
Ê
Install the rear air grid as described in section
"Installing the rear air grid riser
8.6.4.8
Installing the air duct
I
If no GPGPU card is installed in riser module 2 you have to order a new
air duct to direct the airflow directly onto the CPU heat sinks and memory
slots.