RX2540 M2
Upgrade and Maintenance Manual
433
Accessible drives
LTO 3
Figure 317: Connecting the cables to the LTO 3
Ê
Connect the cable C30 to the LTO 3 drive (1).
Ê
Connect the power adapter cable C34 to the LTO 3 drive (2).
I
Don't use the power connector of cable C30.
Cable C30 combines power and SAS connector - however its power
connector is not used in this version! (1).Power is supplied to LTO
drive directly with cable C34! (2). Therefore power adapter cable C31
required additionally.
Ê
Connect the power cable C34 to the power adapter cable C31 (3).
Ê
Connect the power adapter cable C31 to SAS backplane X17.
Ê
Connect the end with the SAS connector cable C30 to the MLC1 connector
of the PSAS controller (4).
Ê
Connect the front panel cable to the system board.