50
Upgrade and Maintenance Manual
RX2540 M2
Important information
Wait until the device has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the device if this
requirement is not observed.
●
Transport the device only in the original packaging or in packaging that
protects it from knocks and jolts.
For the Japanese market, transporting the device in its original packaging
does not apply.
Installation and operation
●
This unit should not be operated in ambient temperatures above 35 °C. For
servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the unit is integrated into an installation that draws power from an industrial
power supply network with an IEC309 connector, the power supply's fuse
protection must comply with the requirements for non-industrial power
supply networks for type A connectors.
●
The server is automatically set to a mains voltage in the range of:
– 100 V to 240 V, valid for Platinum 450 W and Platinum 800 W
– 200 V to 240 V, valid for Titanium 800 W
– 100 V to 120 V / 200 V to 240 V, valid for Platinum 1200 W
You may only operate the server if its rated voltage range corresponds to the
local mains voltage.
As an option, the server can be equipped with a DC hot-plug power supply
unit that adjusts automatically to any power voltage in the range from -40.5 V
to -57 V.
●
This device must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution system with
tested and approved power cords.
●
Ensure that the device is connected to a properly grounded power outlet
close to the device.
●
Ensure that the power sockets on the device and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
device from the mains power supply. In case of repair or servicing
disconnect the device completely from the mains power supply, unplug all
power plugs from the properly grounded power outlets.
Summary of Contents for PRIMERGY RX2540 M2
Page 6: ...Upgrade and Maintenance Manual RX2540 M2 ...
Page 48: ...48 Upgrade and Maintenance Manual RX2540 M2 Before you start ...
Page 128: ...128 Upgrade and Maintenance Manual RX2540 M2 Basic software procedures ...
Page 142: ...142 Upgrade and Maintenance Manual RX2540 M2 Power supply unit PSU ...
Page 392: ...392 Upgrade and Maintenance Manual RX2540 M2 Processor CPU ...
Page 452: ...452 Upgrade and Maintenance Manual RX2540 M2 Accessible drives ...
Page 558: ...558 Upgrade and Maintenance Manual RX2540 M2 System board and components ...
Page 602: ...602 Upgrade and Maintenance Manual RX2540 M2 Appendix ...