RX2540 M2
Upgrade and Maintenance Manual
601
Appendix
The minimum startup configuration consists of the following components and
cables:
Ê
"Shutting down the server" on page 65
Ê
"Disconnecting the power cord" on page 66
Ê
Take the system down to its minimum startup configuration.
Ê
"Connecting the power cord" on page 79
Ê
Connect a keyboard, mouse and display to the server.
Ê
"Switching on the server" on page 82
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
Component
Notes
System board
no TPM, UFM or expansion cards installed
1 CPU with CPU heat sink
installed in CPU slot CPU 1
1 memory module
installed in DIMM slot 1A
Front panel module
1 PSU
installed in PSU bay PSU 1
Table 9: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 10: Minimum startup configuration - cables
Summary of Contents for PRIMERGY RX2540 M2
Page 6: ...Upgrade and Maintenance Manual RX2540 M2 ...
Page 48: ...48 Upgrade and Maintenance Manual RX2540 M2 Before you start ...
Page 128: ...128 Upgrade and Maintenance Manual RX2540 M2 Basic software procedures ...
Page 142: ...142 Upgrade and Maintenance Manual RX2540 M2 Power supply unit PSU ...
Page 392: ...392 Upgrade and Maintenance Manual RX2540 M2 Processor CPU ...
Page 452: ...452 Upgrade and Maintenance Manual RX2540 M2 Accessible drives ...
Page 558: ...558 Upgrade and Maintenance Manual RX2540 M2 System board and components ...
Page 602: ...602 Upgrade and Maintenance Manual RX2540 M2 Appendix ...