64
Upgrade and Maintenance Manual
RX2540 M2
Basic hardware procedures
4.1.3.2
Local diagnostic indicators on the system board
Using the Indicate CSS button
Ê
Shut down and power off the server.
Ê
Disconnect the AC power cord(s) from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
CSS functionality.
Ê
Press the Indicate CSS button to highlight defective components (see
section
"Onboard indicators and controls" on page 584
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section
"Determining the error class" on page 62
).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.