193
PRIMERGY RX300 S3 User's Guide
7
In
st
alling Internal
O
ptions
5
Install memory modules.
Insert the memory module vertically in the memory slot while fitting the concavity.
When the memory module is properly installed, the levers on both sides of the slot are pulled
back. At this time, confirm that the memory module is fixed. If the levers are not pulled back
completely, make sure the levers are pushed inwards.
6
Attach the fan duct and the top cover.
"7.2 Installing/Removing the Top Cover" (pg.182)
7
Push the server back into the rack.
8
Initialize the Extended System Configuration Data (ESCD).
Set [Reset Configuration Data] to [Yes] in the Advanced menu of the BIOS Setup Utility.
See "Reset Configuration Data" in "8.1.5 The Advanced Menu" ( pg.235).
9
Save the BIOS configuration data.
"5.3 Storing the System Configuration Information" (pg.148)
• An improperly inserted memory module may cause a fire. Do not insert the
memory module in the wrong direction.
Lever
Align notch