Chapter 9 Operation and Maintenance
●
A temperature warning is output to the hardware event log and OS event log,
or ServerView issues a notification of a temperature warning such as by a
popup message.
The above log is output or the above notification is issued by ServerView when the ambient temperature
is within 30 to 35
°
C, which is near the upper limit of the temperature boundaries (10 to 35
°
C). This is
to notify the administrator before the ambient temperature actually exceeds the range of the temperature
boundaries.
Although continued use within the temperature boundaries poses no problems within itself, reconsider
the surrounding environment conditions if this log is output or if ServerView issues this notification.
●
POST stops, generating the "Expansion ROM not initialized..." message.
Change [Reset Configuration Data] on "8.1.5 The Advanced Menu" ( pg.235) to [Yes] in the BIOS
Setup Utility.
●
Serial ports are not recognized properly in Device Manager.
This may occur when the Serial 1 and Serial 2 settings are changed with "8.1.6 The Peripheral
Configuration Submenu" ( pg.236) in the [Advanced] menu of the BIOS Setup Utility. If this occurs,
delete all serial ports in Device Manager and restart the system.
■
Display
●
The display does not power on.
Check to see whether the power cable of the display is properly connected to the outlet. For details, refer
to "Start Guide" or the manual of the display.
●
Nothing is displayed on the screen.
• Check to see whether the display cable is connected properly.
If it is not connected, turn the server off and then connect the cable. For the connection location, refer
to "Start Guide".
• Check that the brightness volume and contrast volume of the display are adjusted correctly. If they
need to be adjusted, perform the necessary adjustments.
For details, refer to the manual of the display.
• There may be an error in the system area of the memory. Contact an office listed in the "Contact
Information" of the "Start Guide".
●
Typing the keyboard does not display any characters, or the mouse cursor
does not move.
Check to see whether the keyboard and mouse are connected properly. If they are not connected, turn the
server off and then connect the cables to the server. For the connection location, refer to "Start Guide".
●
The screen shakes.
If a device that produces a strong magnetic field such as a television or speaker is near the display, place
them further away from the display.
Summary of Contents for Primergy RX300 S3
Page 40: ...40 Chapter1 Overview ...
Page 110: ...110 Chapter 3 OS Installation Using ServerStart ...
Page 134: ...134 Chapter 4 Manual OS Installation ...
Page 178: ...178 Chapter 6 High Reliability Tools ...
Page 226: ...226 Chapter 7 Installing Internal Options ...
Page 252: ...252 Chapter 8 Configuring Hardware and Utilities ...
Page 308: ...308 Appendix ...