8.6
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the
Main
menu, using
System Date
and
System Time
respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the "System
Board D3349 for FUJITSU Server PRIMERGY RX4770 M2 Reference
Manual") or contact our customer service team.
8.7
Drives reported as "dead" when starting
system
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
8.8
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.
Summary of Contents for PRIMERGY RX4770 M2
Page 6: ...Operating Manual RX4770 M2 ...
Page 10: ...Operating Manual RX4770 M2 Contents ...
Page 14: ...14 Operating Manual RX4770 M2 Preface ...
Page 28: ...28 Operating Manual RX4770 M2 Functional overview ...
Page 42: ...42 Operating Manual RX4770 M2 Important information ...
Page 78: ...78 Operating Manual RX4770 M2 Property and data protection ...
Page 84: ...84 Operating Manual RX4770 M2 Troubleshooting and tips ...