Install the VRM.
The installing location differs depending on where the CPU was added. Install the VRM in the
VRM slot at the wall side of the server when you added CPU3, install the VRM in the VRM slot
at center side of the server when you added CPU4.
Align a notch of the VRM with the slot and insert the VRM vertically in the slot.
When the module is correctly inserted, the retention clips on both sides will close. Then, check
that the VRM is securely fastened.
If the retention clips are not securely closed, press them closed with your fingers.
13
Install the center brace.
Install the cable through the cable route. At this time, make sure that the cable is not pinched.
After you install it, press the locks on the sides of the server in the direction of the arrow to fasten
it.
14
Install the memory board and its cover.
VRM
VRM Slot (for CPU4, center side of the server)
VRM Slot (for CPU3, wall side of the server)
Cable route
Locks