258
Chapter 9 Operation and Maintenance
●
A temperature warning is output to the hardware event log and OS event log,
or ServerView issues a notification of a temperature warning such as by a
popup message.
The above log is output or the above notification is issued by ServerView when the ambient temperature
is within 30 to 35
°
C, which is near the upper limit of the temperature boundaries (10 to 35
°
C). This is
to notify the administrator before the ambient temperature actually exceeds the range of the temperature
boundaries.
Although continued use within the temperature boundaries poses no problems within itself, reconsider
the surrounding environment conditions if this log is output or if ServerView issues this notification.
●
The following message is displayed on the LCD panel when the server boots.
This message shows that the LAN cable is not connected to the onboard LAN connector.
Check to see whether the LAN cable is connected to the onboard LAN connector.
■
Display
●
The display does not power on.
Check to see whether the power cable of the display is properly connected to the outlet. For details, refer
to the manual of the display.
●
Nothing is displayed on the screen.
• Check to see whether the display cable is connected properly. If it is not connected, turn the server off
and then connect the cable. Video connectors are in the front and rear side. When the display is
connected with both, the connection of the front side is effective. For the connection location, refer to
"1.3 Component Names and Functions" (
• The brightness volume or contrast volume of the display may not be adjusted correctly. If they need
to be adjusted, perform the necessary adjustments.
For details, refer to the manual of the display.
• There may be an error in the system area of the memory. Contact an office listed in the "Contact
Information" of "Start Guide".
●
Typing the keyboard does not display any characters, or the mouse cursor
does not move.
Check to see whether the keyboard and mouse are connected properly. If they are not connected, turn the
server off and then connect the cables to the server. For the connection location, refer to "Start Guide".
●
The screen shakes.
If a device that produces a strong magnetic field such as a television or speaker is near the display, place
them further away from the display.
The display may also shake if a nearby cell-phone receives a call. Do not use a cell-phone near the
display.
BMC 05-05-A6F 440FFF
BMC 05-05-D6F 440FFF
Summary of Contents for Primergy RX600 S2
Page 6: ...6 ...
Page 110: ...110 Chapter 3 OS Installation Using ServerStart ...
Page 132: ...132 Chapter 4 Manual OS Installation ...
Page 228: ...228 Chapter 7 Installing Internal Options ...
Page 286: ...286 Chapter 9 Operation and Maintenance ...
Page 298: ...298 ...