261
PRIMERGY RX600 S2 User’s Guide
9
O
p
eration
a
nd
Mainten
ance
0146
Insufficient Memory to Shadow PCI
ROM
PCI ROM error. Check that the PCI card is mounted
properly. If the message still appears, the PCI card or the
PCI slot must be replaced. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
8110-8113
Processor n Internal error (IERR)
CPU error ("n" in the message represents the CPU socket
number). Set [Processor Retest] on the [Processor] menu
to [Enabled] in the BIOS Setup Utility, reboot the system,
and confirm the CPU connection. If the message still
appears, the CPU must be replaced. If the message still
appears after the replacement, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
8120-8123
Processor n Thermal Trip Error
CPU error ("n" in the message represents the CPU socket
number). After confirming that the heat sink, the fan, and
the airflow work normally, set [Processor Retest] on the
[Processor] menu to [Enabled] in the BIOS Setup Utility,
and reboot the system. If the message still appears, the
CPU must be replaced.
8130-8133
Processor n Disabled
CPU error ("n" in the message represents the CPU socket
number). After confirming whether there are any errors
reported in the system event log, set [Processor Retest] on
the [Processor] menu to [Enabled] in the BIOS Setup
Utility, and reboot the system. If the message still
appears, replace the CPU. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
8140-8143
Processor n Failed FRB-3 timer
CPU error ("n" in the message represents the CPU socket
number). Start the BIOS Setup Utility, set [Processor
Retest] on the [Processor] menu to [Enabled], and reboot
the system. If the message still appears, replace the CPU.
If the message still appears after the replacement, the
baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
8160-8163
Processor n unable to apply microcode
update
CPU error ("n" in the message represents the CPU socket
number). Start the BIOS Setup Utility, set [Processor
Retest] on the [Processor] menu to [Enabled], and reboot
the system. If the message still appears, replace the CPU.
If the message still appears after the replacement, the
baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
8170-8173
Processor n failed BIST
8180-8183
BIOS does not support the current
stepping for processor n
8190
Watchdog Timer Failed on Last Boot
Boot Watchdog Timer has timed out. View the system
event log and confirm whether any errors have been
recorded.
8198
Operating system boot watchdog timer
failure
table: List of POST Errors
Error
Code
Message
Description
Summary of Contents for Primergy RX600 S2
Page 6: ...6 ...
Page 110: ...110 Chapter 3 OS Installation Using ServerStart ...
Page 132: ...132 Chapter 4 Manual OS Installation ...
Page 228: ...228 Chapter 7 Installing Internal Options ...
Page 286: ...286 Chapter 9 Operation and Maintenance ...
Page 298: ...298 ...