262
Chapter 9 Operation and Maintenance
0192
L3 cache size mismatch
Processors with different L3-cache sizes are installed.
Confirm that all the CPUs mounted are of the same
model. After the confirmation, start the BIOS Setup
Utility, set [Processor Retest] on the [Processor] menu to
[Enabled], and reboot the system. After the reboot,
confirm that all the CPUs mounted are of the same model.
If the message still appears, replace the CPU. If the
message still appears after the replacement, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
0193
CPUID, Processor stepping are
different
CPU error. Start the BIOS Setup Utility, set [Processor
Retest] on the [Processor] menu to [Enabled], and reboot
the system. After the reboot, confirm that all the CPUs
mounted are of the same model. If the message still
appears, replace the CPU. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
0194
CPUID, Processor family are different
0195
Front side bus mismatch
0196
CPUID, Processor Model are different
CPUs of different models are installed. Set [Processor
Retest] on the [Processor] menu to [Enabled] in the BIOS
Setup Utility, reboot the system, and confirm that all the
mounted CPUs are of the same model. If CPUs of the
same model are mounted but the message still appears,
replace the CPU. If the message still appears after the
replacement, the baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start
Guide".
0197
Processor speeds mismatched
CPUs with different frequencies are installed. Set
[Processor Retest] on the [Processor] menu to [Enabled]
in the BIOS Setup Utility, reboot the system, and confirm
that all the mounted CPUs are of the same model. If
CPUs of the same model are mounted but the message
still appears, replace the CPU. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
8300
Baseboard Management Controller
failed Self Test
BMC error. Check the jumper setting (
Settings" (Pg.231)). If the message still appears, the
baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
8306
Front Panel Controller Locked
Front panel error. Replace the front panel. If the message
still appears, the baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start
Guide".
8305
Hotswap Controller Failed
SCSI backpanel board error. Replace the SCSI backpanel
board. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
table: List of POST Errors
Error
Code
Message
Description
Summary of Contents for Primergy RX600 S2
Page 6: ...6 ...
Page 110: ...110 Chapter 3 OS Installation Using ServerStart ...
Page 132: ...132 Chapter 4 Manual OS Installation ...
Page 228: ...228 Chapter 7 Installing Internal Options ...
Page 286: ...286 Chapter 9 Operation and Maintenance ...
Page 298: ...298 ...