8420
Intelligent System Monitoring Chassis
Opened
Baseboard error. The baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
84F2
Baseboard Management Controller
failed to respond
84F3
Baseboard Management Controller in
Update Mode
84F4
Sensor Data Record Empty
84FF
System Event Log Full
The writing area for the system event log is full. Remove
older system event logs. If the message still appears after
clearing the system event logs, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
8500-
85DB
Board: n, DIMM: n Memory bad or
missing
Memory error ("n" in the message represents the memory
board/slot number). Check that the memory is mounted
properly. If the message appears although the installation
is correct, replace the memory. If the message still
appears, replace the memory board. If the message still
appears after the replacement, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Board: n, DIMM: n Memory not
configured
Board: n, DIMM: n Memory disabled
Board: n, DIMM: n Memory mismatch
Board: n, DIMM: n Memory
correctable ECC error
Board: n, DIMM: n Memory
uncorrectable ECC error
Board: n, DIMM: n Memory invalid
speed
85E0
85E8
85F0
85F8
Board: n Memory bad or missing
Memory error ("n" in the message represents the memory
board/slot number). Check that the memory is mounted
properly. If the message appears although the installation
is correct, replace the memory. If the message still
appears, replace the memory board. If the message still
appears after the replacement, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
85E1
85E9
85F1
85F9
Board: n Memory not configured
The installation configuration of the memory is wrong
("n" in the message represents the memory board/slot
number). Confirm the memory configuration and the
information on the installed memories using the BIOS
Setup Utility. If the message appears although the
installation is correct, replace the memory. If the message
still appears, replace the memory board. If the message
still appears after the replacement, the baseboard must be
replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
85FC
System Memory bad or missing
System memory error. Check that the memory is mounted
properly. If the message appears although the installation
is correct, replace the memory board. If the message still
appears, replace the memory. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
table: List of POST Errors
Error
Code
Message