34
Service Supplement
RX600
S6
Replacement routines
Installing the hot-swap backplane
Figure 15: Installing the hot-swap backplane
Ê
Set the hot-swap backplane into position by lowering it over the metal tabs
(see arrows in figure above).
Ê
Plug all relevant cables into the hot-swap backplane (see the cabling plan in
the appendix of the Options Guide).
Ê
Plug the cable from the power distribution board to the front panel fan board.
Ê
Plug the cable from the system board to the front panel fan board.
Ê
Reinstall the memory rug (see
figure 13 on page 32
).
Ê
Push all HDD/SSD modules and the optical drive back into their bays in the
housing until they engage.
Ê
Plug all memory boards and memory dividers back into their slots.
Ê
Close the server as described in
section "Closing the server" on page 22
.
This completes the replacement of the hot-swap backplane.