RX600 S6
Service Supplement
45
Replacement routines
Ê
Carefully shift the system board to the back side of the housing so that it fits
into the grounding brackets (see ovals in figure above).
V
CAUTION!
Always take the system board with both hands!
Don’t damage the EMI springs which are essential to comply with
applicable EMC regulations and satisfy cooling requirements and fire
protection measures.
Ê
If present, reinstall the TPM (see
page 48
).
Ê
Connect all cables to the system board.
Ê
Reinstall the memory rug (see
figure 13 on page 32
).
Ê
Install both BBU holders.
Ê
Install the battery (if present) and line the BBU cable in the sidewall of the
housing before installing the mid-brace.
Ê
Reinstall the heat sinks (see the Options Guide).
Ê
Install the mid-brace by fastening the six screws (see
figure 22 on page 42
).
Figure 25: Installing the hot-plug PCI divider insert