RX900 S1
Maintenance Manual
85
Hard disk and solid state drives
6.2.2
Starting the task
Ê
Perform the following procedures:
1.
"Opening the rack door" on page 40
2.
"Locate the faulty server" on page 37
3.
"Locate the faulty component by PRIMERGY diagnostics indicators" on
page 39
Only applicable for removing non-defective HDD/SSD modules:
Ê
Set the drive to "Offline" via the software (RAID controller configuration
software), before removing an HDD/SSD module that is not defective.
6.2.3
Unlocking the HDD/SSD module
Figure 37: Unlocking the 2.5-inch HDD/SSD module
Ê
Release the locking mechanism as follows:
1. Press the two green tabs of the locking lever together (1).
2. Push the handle of the HDD/SSD module fully in the direction of the
arrow (2). The HDD/SSD module is now unlocked.
2
1