TX100 S2
Service Supplement
39
Replacement routines
4.1.5
Replacing accessible drives
4.1.5.1
Removing accessible drives
The following replacement routines require removing accessible drives:
–
Replacing the front panel cable
–
Replacing the front USB module
–
Replacing the power supply unit
(optional)
Ê
Shut down the server and disconnect the AC power cord from the system.
Ê
Remove the side cover as described in section
4.1.1.1 on page 23
.
Ê
Open the HDD cage as described in section
4.1.2.1 on page 25
.
Figure 17: Removing accessible drives (A)
Ê
Remove four screws from each accessible drive.
Ê
Disconnect all cables from the accessible drives.