Important notes
Installation and operation
V
CAUTION!
●
This unit should not be operated in ambient temperatures above
35 °C.
●
If the unit is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of
100 V - 240 V. Ensure that the local mains voltage lies within these
limits.
●
This device must only be connected to properly grounded power
outlets or insulated sockets of the rack's internal power supply with
tested and approved power cords.
●
Ensure that the device is connected to a grounded power outlet close
to the device.
●
Ensure that the power sockets on the device and the grounded power
outlets are freely accessible.
●
The On/Off button or the main power switch (if present) does not
isolate the device from the mains power supply. To disconnect it
completely from the mains power supply, unplug all network power
plugs from the grounded power outlets.
●
Always connect the server and the attached peripherals to the same
power circuit. Otherwise you run the risk of losing data if, for example,
the server is still running but a peripheral device (e.g. memory
subsystem) fails during a power outage.
●
Data cables must be adequately shielded.
●
The EN 50173 and EN 50174-1/2 standards apply for LAN cabling.
The minimum requirement is the use of a category 5 screened LAN
cable for 10/100 Mbit/s Ethernet, or a category 5e cable for Gigabit
Ethernet. The requirements from the ISO/IEC 11801 specification
must also be met.
●
Route the cables in such a way that they do not create a potential
hazard (make sure no-one can trip over them) and that they cannot
be damaged. When connecting the server, refer to the relevant
instructions in this manual.