72
Operating Manual
TX100 S2 Core Edition
Installation and operation
I
At least two hard disk drives must be installed when resetting your
server. In order to prevent additional hard disk drives from being
overwritten, proceed as described in
recovery with 4-HDD configurations" on page 85
.
Ê
In order to initiate the rebuild and installation process, confirm the warning
message.
V
Once the installation has been started, the device must not be
switched off unless the DVD tray opens, indicating that the installation
process is complete.
I
The RAID array rebuild and recovery installation will be performed
completely unattended. The server will reboot several times during
the process. The VNC connection will be closed upon the first reboot
and can be re-established about three minutes later for a limited time
to monitor the installation progress.
Ê
Wait until the DVD tray opens, indicating that the installation process is
complete.
I
The system can now be used, however, data redundancy will not be
available until the RAID array rebuild is complete. Depending on the
hard disk drive capacity the overall process can take up to several
hours.
Ê
Remove the Maintenance & Recovery DVD and close the DVD tray.
Ê
Perform steps 3 through 5 in
section "Initial operation" on page 47
to finalize the operating system installation and starting up your server.