86
Operating Manual
TX100 S2 Core Edition
Troubleshooting and tips
Ê
Power on your Headless server and establish a VNC connection as
described in section
section "Accessing the server using a VNC connection"
.
Select
Create RAID and Reinstall
from the
Recovery
section in the
Maintenance and Recovery Manager menu (see
Ê
After the rebuild and installation process is complete, shut down your server
and reconnect the additional hard disk drives to SATA connectors "SATA 2"
and "SATA 3" as described above.
Ê
Complete the initial configuration of your Headless server as described in
section "Initial operation" on page 47
Ê
Use the ServerView RAID Manager to recreate the RAID array including the
two additional hard disk drives (IDs 2 and 3) according to the RAID
configuration values you have noted down before resetting the Headless
server.
V
CAUTION!
Before clicking the
Create
button, ensure that
Init mode
is set to
No
initialization
! Otherwise the user data on the additional hard disk
drives will be lost!
7.10
Power-on indicator reports an error
It is no longer possible to establish a Remote Desktop connection or
access any service or file on the Headless server. Additionally the Power-
on indicator reports an error by flashing continuously.
There are two different error states indicated by the the Power-on indicator:
The Power-on indicator flashes at a high frequency (2 Hz, twice every
second).
This error state indicates that an error occurred during the early BIOS POST
phase. The system is unable to finish the BIOS POST phase successfully due
to an error involving the system board. Additionally a beep code might be
audible. A typical error cause might be an improperly seated memory module.
In order to resolve such problems, proceed as follows: