TX1310 M3
Operating Manual
19
Functional overview
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Electrical values of the PSU
Floorstand (W x D x H) 179.95 x 312.9 x 373.95 mm
Weight
max. 12 kg
(depending on configuration)
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5 °C ... 40 °C (with ATD 40 °C)
10 °C ... 35 °C
Transport (2K2)
-25 °C ... 60 °C
Humidity
10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296)
< 3.7 B (standby)
< 4.0 B (operation)
Sound pressure level at adjacent position
L
pAm
(ISO 9296)
< 24 dB (A) (standby)
< 24 dB (A) (operation)
Power supply configuration
Standard power supply
Max. output
250 W
Rated voltage range
100 V - 240 V
Rated frequency range
50 Hz - 60 Hz
Rated current
max. 3.3 A – 1.3 A (100 V / 240 V)
Summary of Contents for PRIMERGY TX1310 M3
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY TX1310 M3 Operating Manual January 2018 ...
Page 7: ...TX1310 M3 Operating Manual Contents 8 12 Optical drive cannot read data 67 ...
Page 8: ...Operating Manual TX1310 M3 Contents ...
Page 12: ...12 Operating Manual TX1310 M3 Introduction ...
Page 22: ...22 Operating Manual TX1310 M3 Functional overview ...
Page 38: ...38 Operating Manual TX1310 M3 Important information ...
Page 46: ...46 Operating Manual TX1310 M3 Hardware installation ...
Page 60: ...60 Operating Manual TX1310 M3 Starting up and operation ...
Page 62: ...62 Operating Manual TX1310 M3 Property and data protection ...
Page 68: ...68 Operating Manual TX1310 M3 Troubleshooting and tips ...