108
Upgrade and Maintenance Manual
TX1320
M1
Power supply
6.1
Standard power supply unit
6.1.1
Replacing the standard power supply unit
6.1.1.1
Preliminary steps
Before replacing the standard PSU, perform the following steps:
I
You are advised to perform this routine with the server in a horizontal
position.
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 73
.
Ê
Locate the defective server as described in section
"Locating the defective
server" on page 44
.
Ê
Shut down the server as described in section
"Shutting down the server" on
page 52
.
Ê
Disconnect the AC power cord from the system.
Ê
Remove the server cover as described in section
"Opening the server" on
page 55
.
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
tool-less (preliminary and concluding steps)
Phillips PH2 / (+) No. 2 screw drive (replacing the PSU)
Summary of Contents for PRIMERGY TX1320 M1
Page 18: ...Upgrade and Maintenance Manual TX1320 M1 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX1320 M1 Important information ...
Page 106: ...106 Upgrade and Maintenance Manual TX1320 M1 Basic software procedures ...
Page 150: ...150 Upgrade and Maintenance Manual TX1320 M1 Hard disk drives solid state drives ...
Page 280: ...280 Upgrade and Maintenance Manual TX1320 M1 Front panel ...
Page 320: ...320 Upgrade and Maintenance Manual TX1320 M1 Cables Figure 200 Cabling with extension box ...