Converting a tower model to a rack model
Removing the accessible drive cage
Ê
Remove the front panel module as described in section
"Removing the
defective front panel module" on page 247
.
Ê
If applicable, remove all accessible drives as described in section
"Removing an accessible drive" on page 240
.
Figure 191: Detaching the accessible drive cage (A)
Ê
Remove two screws from the bottom side of the server as shown.
Ê
Bring the server back to its horizontal position.
I
At least two people are needed to turn over a fully equipped server.
Remove hard disk drives and power supply units in order to facilitate
the task.