330
Upgrade and Maintenance Manual
TX140
S2
Appendix
17.4 Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
"Shutting down the server" on page 46
Ê
"Disconnecting the server from the mains" on page 46
Ê
Take the system down to its minimum startup configuration.
Ê
"Connecting the server to the mains" on page 67
Ê
Connect a keyboard, mouse and display to the server.
Ê
"Switching on the server" on page 68
Field Replaceable Units (FRU)
Component
Notes
System board
no TPM, UFM or expansion cards installed
CPU with CPU heat sink
1 memory module
installed in DIMM slot 1A
Front panel module
Power supply unit
Table 9: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 10: Minimum startup configuration - cables
Summary of Contents for PRIMERGY TX140 S2
Page 30: ...30 Upgrade and Maintenance Manual TX140 S2 Before you start ...
Page 98: ...98 Upgrade and Maintenance Manual TX140 S2 Basic software procedures ...
Page 120: ...120 Upgrade and Maintenance Manual TX140 S2 Power supply ...
Page 148: ...148 Upgrade and Maintenance Manual TX140 S2 Hard disk drives solid state drives ...
Page 158: ...158 Upgrade and Maintenance Manual TX140 S2 System fan and air duct ...
Page 208: ...208 Upgrade and Maintenance Manual TX140 S2 Expansion cards and backup units ...
Page 216: ...216 Upgrade and Maintenance Manual TX140 S2 Main memory ...
Page 314: ...314 Upgrade and Maintenance Manual TX140 S2 Cabling ...
Page 332: ...332 Upgrade and Maintenance Manual TX140 S2 Appendix ...