40
Operating Manual
TX150
S5
Installing/Removing the Rack Model
Hardware Installation
–
You must ensure that the safety mechanisms on the server, e.g. stoppers or
retaining systems, are functioning correctly.
–
The shape of the rack support uprights must ensure that the telescopic rails
can be bolted at the front.
–
Front bolted telescopic rails.
The rails have a linear alignment feature to ensure that they can be adjusted
to different rack depths.
–
No support for cable management system (included in installation kit).
–
Climatic conditions.
To ventilate the server, an unimpeded air inlet on the front of the rack and an
air outlet on the rear of the rack are required.
In principle the ventilation concept is based on the necessary cooling being
provided by the horizontal self-ventilation of the installed devices (air flow
from front to back).
–
Power supply:
For installation in 3rd party racks it must be ensured that the appropriate
socket strips are present.