Hardware Installation
Installing/Removing the Rack Model
4.4.3
Installation in 3rd Party Racks
The following parts are required to install the server in 3rd party racks:
–
Support bracket
–
Two variable rails and two telescopic rails
–
Possibly protective hose for fiber channel fiber optic cable
Ê
Refer to the original manual from the rack manufacturer for details of the
mechanical installation and the climatic conditions.
V
CAUTION!
For installation in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê
Fit the required original parts (support bracket or cable management
system).
I
Under certain circumstances, you will not be able to use some of the
parts from the rack installation kit supplied - you will need to use
original 3rd party rack parts instead.
Ê
Fit the prepared rails in the 3rd party rack, as described in section
lation in PRIMECENTER/DataCenter Rack” on page 42
Ê
Insert the server (see section
“Inserting the server” on page 54
Ê
Route the cables as described in the original rack manual.