Starting Up and Operation
Controls and Displays
LED
orange
HDD FAULT (in conjunction with a disk array controller)
●
SAS Server Variant
–
Not lit: No HDD error
–
Lit: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, drive failed, drive deactivated by software or the
HDD module is not correctly inserted)
–
Slow flashing: HDD Rebuild (the data is being restored after
changing a hard disk drive)
–
Fast flashing: HDD Identify
●
SATA Server Variant
–
Not lit: No HDD error
–
Lit: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the HDD module
is not correctly inserted)
–
Slow flashing: HDD Rebuild (the data is being restored after
changing a hard disk drive)
–
Fast flashing: HDD Identify
–
Fast flashing (four times/pause): HDD Predicted Fault
(probable drive error)
(not applicable for the PCI SATA RAID controller)
–
Two fast flashes/pause: HDD Hot Spare (Hot spare drive
active. The corresponding drive has failed).