TX150 S5
Service Supplement
25
Replacement routines
Replacing the standard PS
Figure 7: Taking out the standard PS
Ê
Slide the standard power supply somewhat toward the inside (1) to detach it
from the adapter plate and take the standard power supply out toward the
side (2).
Ê
Push the new power supply into the bay. Take care not to trap the cables.
Ê
Fasten the power supply with four screws to the adapter plate.
Ê
Connect all power cables to the system board and the drives (see the cabling
plans in the Appendix of the Options Guide).
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
V
CAUTION!
After replacing the standard power supply a fan calibration must be
started. You will find the description for this procedure in the manual
“ServerStart“.
2
1