TX150 S5
Operating Manual
37
Hardware Installation
Installing/Removing the Rack Model
4.4
Installing/Removing the Rack Model
V
CAUTION!
●
Follow the safety instructions and the rack installation instructions in
chapter
“Important Information” on page 19
●
At least two people are needed to install / remove the server in the
rack.
●
The rack may tip over if more than one unit is removed at the same
time.
●
The server may not occupy the top height unit of the rack (42 HU
Classic Rack, 38 HU/42HU PRIMECENTER Rack and/or DataCenter
Rack), as otherwise boards cannot be replaced even with the plug-in
module fully extended.
Rack requirements
The Fujitsu Siemens Computers GmbH PRIMECENTER Rack; DataCenter
Rack and 19” (Classic) Rack provide full support for installation of the
PRIMERGY server system. Installation in most current rack systems from other
manufacturers (3rd party racks) is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
The main features of the Fujitsu Siemens Computers GmbH rack systems are:
PRIMECENTER Rack
–
Front bolted telescopic rails (a support bracket is used in the lower left area).
The rails have a linear alignment feature to ensure that they can be adjusted
to different rack depths.
–
Enhanced cable management in the lateral rack area.