44
Operating Manual
TX150
S5
Installing/Removing the Rack Model
Hardware Installation
Figure 8: Fitting the rails in the rack
Ê
Position the left-hand rail (1) on the support bracket (b) (insert horizontal
lug (3)).
Ê
Clamp the left-hand rail (2) between the front left support upright and the
support bracket by pressing the rail together, positioning it on the front
support upright and releasing them again. The rail automatically adjusts to
the rack depth.
Ê
Secure the rail on the support upright (a) and the support bracket (b) with
two M5x10 screws inc. plug washers in each case.
Ê
Repeat the above steps with the right-hand rail (it is secured to the front and
rear right support upright).
Ê
Fit the PRIMECENTER/DataCenter Rack cable management system (artic-
ulated cable guide) as described in the Technical Manual for the corre-
sponding rack.
Ê
Insert the server (see section