Functional overview
Noise level (depending on the configuration)
The acoustic noise values are depending on the system configuration.
Electrical data: 450 W Platinum
Electrical data: 800 W Platinum
Electrical data: 1200 W Platinum
Electrical data: 800 W Titanium
Standard configuration
Sound power level
L
WAd
(ISO 9296)
4.2 B (standby)
4.8 B (operation)
Sound pressure level at adjacent workstation
L
pAm
(ISO 9296)
24 db(A) (standby)
30 db(A) (operation)
Rated voltage range
100 V - 240 V
Frequency
50 Hz / 60 Hz
Max. rated current
5.0 A - 2.0 A
Rated voltage range
100 V - 240 V
Frequency
50 Hz / 60 Hz
Max. rated current
9.0 A - 3.5 A
Rated voltage range
100-120 V / 200-240 V
Frequency
50 Hz / 60 Hz
Max. rated current
10.5 A (100-120 V) / 5 A (200-240 V)
Rated voltage range
200 V - 240 V
Frequency
50 Hz / 60 Hz
Max. rated current
4.5 A