68
Operating Manual
TX2550 M4
Starting up and operation
I
Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
I
For more details on detected errors, see the System Event Log (SEL) or
use the ServerView Operations Manager or iRMC S5 web interface.
Pos. Indicator
Status
Description
1
ID indicator,
see also
"iRMC-
related
status
signals" on
page 64
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
interface or the ID button on the front panel for
easy identification.
blue
flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 64
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified temperature
range
– Defective sensor
– CPU error
– Error detected by server management
software
CSS
indicator
off
No critical event detected (CSS component).
orange
on
Prefailure event detected (CSS component).
orange
flashing
CSS component failure detected.
Summary of Contents for PRIMERGY TX2550 M4
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M4 Operating Manual May 2018 ...
Page 8: ...Betriebsanleitung TX2550 M4 Contents ...
Page 12: ...12 Operating Manual TX2550 M4 Introduction ...
Page 30: ...30 Operating Manual TX2550 M4 Functional overview ...
Page 46: ...46 Operating Manual TX2550 M4 Important information ...
Page 58: ...58 Operating Manual TX2550 M4 Hardware installation ...
Page 82: ...82 Operating Manual TX2550 M4 Property and data protection ...