86
Operating Manual
TX2550 M4
Troubleshooting and tips
8.7
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the Main menu, using System Date and System Time respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under
Linux, and would overwrite the system time in the default setting on
shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the
"FUJITSU Server PRIMERGY TX2550 M4 Upgrade and Maintenance Manual")
or contact our customer service team.
8.8
System will not boot
The system will not boot after installing a new hard disk drive.
SAS configuration incorrect
Ê
Check the settings for the hard disk drives (SAS Device Configuration) and
the additional settings in the SAS configuration menu.
8.9
HDD error messages at system boot
Various HDD error messages may occur when the system is rebooted. These
error messages are caused by modifications in the selected RAID configuration.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller
configuration program.
For more information, see the documentation for the RAID controller.
Summary of Contents for PRIMERGY TX2550 M4
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M4 Operating Manual May 2018 ...
Page 8: ...Betriebsanleitung TX2550 M4 Contents ...
Page 12: ...12 Operating Manual TX2550 M4 Introduction ...
Page 30: ...30 Operating Manual TX2550 M4 Functional overview ...
Page 46: ...46 Operating Manual TX2550 M4 Important information ...
Page 58: ...58 Operating Manual TX2550 M4 Hardware installation ...
Page 82: ...82 Operating Manual TX2550 M4 Property and data protection ...