TX2550 M4
Operating Manual
55
Hardware installation
Connecting the keyboard, mouse and monitor
Ê
Connect the monitor, the keyboard and the mouse to the standard ports of
the server.
Ê
Connect the power cable of the monitor to a grounded mains outlet of the in-
house mains and/or to the mains socket strip of the rack.
V
CAUTION!
The rated current for the monitor is indicated on the technical data label
on the monitor or in the operating manual for the monitor.
5.5
Connecting the server to the mains
In its basic configuration level the server has one PSU.
A second PSU can be added to ensure a redundant power supply. If one PSU
is defective, the other then guarantees unimpaired operation. In this case. the
defective PSU can be replaced during operation (see the "FUJITSU Server
PRIMERGY TX2550 M4 Server Upgrade and Maintenance Manual").
V
CAUTION!
The server supports a mains voltage the range of 100 V - 240 V (AC
PSUs Platinum) or 200 V - 240 V (AC PSU Titanium, 800 W). You may
only operate the server if its rated voltage range corresponds to the local
mains voltage.
Ê
Connect the power cord to the server PSU.
Ê
Connect the power cord to a grounded mains outlet in the in-house power
supply network or a power outlet of the socket strip in the rack.
I
A phase redundancy in the power supply of the server can be set up if
two hot-plug PSUs are installed.
In this case, each of the PSUs is either connected to two different phases
or to two separate circuits of the internal power supply network.
Summary of Contents for PRIMERGY TX2550 M4
Page 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M4 Operating Manual May 2018 ...
Page 8: ...Betriebsanleitung TX2550 M4 Contents ...
Page 12: ...12 Operating Manual TX2550 M4 Introduction ...
Page 30: ...30 Operating Manual TX2550 M4 Functional overview ...
Page 46: ...46 Operating Manual TX2550 M4 Important information ...
Page 58: ...58 Operating Manual TX2550 M4 Hardware installation ...
Page 82: ...82 Operating Manual TX2550 M4 Property and data protection ...