Installing/removing the rack model
Hardware installation
4.3.1
Installation in PRIMECENTER/DataCenter Rack
For installation in a PRIMECENTER/DataCenter Rack, the following parts are
required:
–
Support bracket
–
One support system on the left and one on the right (mounted)
–
M5 centering fixtures (screws with integrated plugwashers)
I
–
The descriptions and figures in this section refer to the current
variable support.
–
You can find general information regarding server installation in the
rack in the technical manual for the appropriate rack.
When mounting the left telescopic rail in the corresponding rack, the supplied
support bracket must first be mounted flush with the underside of the device on
the rear left support upright.
Figure 4: Fitting the support bracket
Ê
Position the support bracket at the corresponding height on the rear left
support upright, (place knob(s) in corresponding hole(s) and secure it with
the two supplied M5 centering fixtures.
Two versions of the support system are available:
–
with two screw holes each front and rear
–
with two retaining bolts rear and a screw hole front