Service Supplement TX600 S3
29
Replacement routines
Replacing the BMC board
4.5
Replacing the BMC board
The server has a baseboard management controller, the so-called BMC board.
This board is located on the system board and is concealed by the memory
boards installed in slots “A” and “B” (see Technical Manual for the system board
D1651).
Requirements
–
The server has been switched off
–
The power cables have been uplugged
–
Rack model only: The server has been pulled out
–
The housing cover has been removed
–
The memory boards in slots “A” and “B” have been removed
Removing the BMC board
Figure 11: Removing the BMC board
Ê
Hold the BMC board with both hands (see (A) in the figure above).
V
Caution!
Do not bend or twist the board.