8 Defining network paths (LAN)
8.1.2
Defining a single network
In VIOM, a single network refers to a network in which a server blade can
communicate externally via one or several uplink ports. The uplink ports are
grouped in an uplink set. The network is given the same name as the uplink
set.
By grouping several active uplink ports in an uplink set and assigning an
uplink set to a network, a link aggregation group (LAG) can be formed. Since
it is possible to use several connections simultaneously in a LAG, you can
achieve a higher transmission speed and greater level of reliability in the net-
work.
A static LAG is formed by default, i. e. the LACP protocol is not sup-
ported. Please note that the ports on the external switch, which are
connected to the IBP ports that form a LAG, have to form a static
LAG if the LAG on the IBP forms a static LAG.
You can optionally enable the LACP mode when creating a network.
If the LAG on the IBP is configured to use LACP, the LAG on the
external switch must also be configured to use LACP.
Note: The Link Aggregation Control Protocol (LACP) is defined in
IEEE 802.3ad, which allows dynamic trunking of two or more net-
work connections between two switches.
For a single network, no VLAN IDs are taken into account, i. e. all packages
are allowed through irrespective of the VLAN ID.
To define an single network, follow the steps below:
1. Click on the
Ext. LAN Connections
tab in in the work area on the left.
2. Start the
Create network
wizard by:
l
clicking
New
on the
Graphic
or
Details
tabs
l
selecting
New Uplink Set
in the context menu of an uplink set.
The
Create network
wizard is launched.
280
ServerView Virtual-IO Manager
Summary of Contents for ServerView Virtual-IO Manager V3.1
Page 10: ...10 ServerView Virtual IO Manager ...
Page 56: ...56 ServerView Virtual IO Manager ...
Page 276: ...276 ServerView Virtual IO Manager ...
Page 300: ...300 ServerView Virtual IO Manager ...
Page 302: ...302 ServerView Virtual IO Manager ...
Page 312: ...312 ServerView Virtual IO Manager ...
Page 330: ...330 ServerView Virtual IO Manager ...
Page 352: ...352 ServerView Virtual IO Manager ...
Page 362: ...362 ServerView Virtual IO Manager ...