SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
8.3
I/O Unit Replacement
The I/O units are cold replacement components.
8.3.1
Accessing the I/O Unit
Caution –
There is an electrical hazard if the power cords are not disconnected. All
power cords must be disconnected to completely remove power from the server.
●
Power off the server.
This step includes turning the key switch to the Service position, confirming that the
POWER LED is off, and disconnecting power cables. See
Server Off Using Software” on page 4-12
8.3.2
Removing the I/O Unit
Caution –
Use proper ESD grounding techniques when handling components. See
Section 1.1, “Safety Precautions” on page 1-1
.
1. Disconnect and label all the cables that connect to the I/O unit.
2. Remove the cassettes from the I/O unit.
See
Section 8.1.2, “Removing the PCI Cassette” on page 8-5
3. Disconnect the cabinet end of the cable management arm.
Summary of Contents for SPARC Enterprise M4000
Page 4: ......
Page 62: ...2 38 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 89: ...Chapter 5 Internal Components Access 5 7 FIGURE 5 4 Removing the M5000 Server Top Cover ...
Page 126: ...6 34 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 132: ...7 6 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 158: ...8 26 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 245: ...Chapter 14 Backplane Unit Replacement 14 11 FIGURE 14 4 Removing the M5000 Server Backplane ...
Page 248: ...14 14 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 256: ...15 8 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 288: ...E 6 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 304: ...F 16 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...
Page 308: ...G 4 SPARC Enterprise M4000 M5000 Servers Service Manual December 2010 ...