Chapter 25
Addition, Deletion, and Upgrade of FRU
25-17
12. Power on the target domain, and apply OpenBoot PROM firmware.
It stops at
ok
prompt. It is not necessary to start Oracle Solaris OS.
13. Check the updated OpenBoot PROM version.
In the following output sample, the OpenBoot PROM version of XCP 1100 is 02.17.0000.
14. Power off the target domain.
15. By using XSCF, add the upgraded CPU to the existing CMU.
a. Execute the
replacefru
(8) command and select "CMU/IOU" from the
maintenance menu.
Section 6.2, “Active Replacement and Hot Replacement” on page 6-5
,
perform the replacement operation according to the instructions displayed in the
maintenance menu.
For details on how to add CPU module (CPUM) to CMU, see
Module Replacement” on page 6-25
Caution –
To the CMU on which the add-on CPU mounted, do not fail to execute the
diagnostic test which is provided in the maintenance menu of the
replacefru
(8)
command.
16. Confirm that the mounted CPU module has been recognized by the server, and the
error indicator asterisk (*) is not displayed.
XSCF>
poweron -d
domain_id
XSCF>
version -c cmu -v
DomainID 00 : 02.03.0000
DomainID 01 : 02.03.0000
DomainID 02 : 02.17.0000
DomainID 03 : 02.17.0000
...
DomainID 15 : 02.03.0000
XSB#00-0 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-1 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-2 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#00-3 : 02.03.0000 (Current), 02.02.0000 (Reserve)
XSB#01-0 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-1 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-2 : 02.03.0000 (Reserve), 02.17.0000 (Current)
XSB#01-3 : 02.03.0000 (Reserve), 02.17.0000 (Current)
...
XSCF>
poweroff -d
domain_id
XSCF>
replacefru
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 15: ...Contents xv Index Index 1 ...
Page 16: ...xvi SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 22: ......
Page 27: ...Chapter 1 Safety and Tools 1 5 M9000 Server Front View ...
Page 29: ...Chapter 1 Safety and Tools 1 7 Power Supply Unit PSU ...
Page 38: ...1 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 88: ...2 50 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 148: ......
Page 154: ...5 6 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 205: ...Chapter 7 I O Unit IOU Replacement 7 13 FIGURE 7 8 Removing the IOU Front of M9000 1 1 2 3 ...
Page 227: ...Chapter 8 FAN Unit Replacement 8 11 FIGURE 8 9 Removing the FAN Unit Rear of M8000 1 2 ...
Page 256: ...10 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 272: ...11 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 312: ...13 30 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 340: ...15 14 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 358: ...17 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 370: ...18 12 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 380: ...19 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 409: ...Chapter 20 Backplane Replacement 20 29 FIGURE 20 16 Removing the FANBP Rear of the M8000 ...
Page 422: ...21 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 439: ...Chapter 23 Switch Backplane Replacement 23 7 FIGURE 23 4 Removing the SWBP Rear of the M8000 ...
Page 442: ...23 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 460: ...24 18 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 484: ...25 24 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 494: ...A 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 544: ...C 4 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 552: ...D 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...