36
SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1092 • April 2010
RTIF1-
070528-002
While XSCF is running, watchdog timeout
may occur and XSCF may reboot.
Check that XSCF is started. If not started, stop
all the domains and then execute the system
power off/on (AC OFF/ON). To turn on the
system power that you turned off, wait at least
30 seconds before power-on.
RTIF1-
070802-001
When connected to telnet, the login or the
password prompt doesn't appear.
Disconnect the telnet session and try again.
RTIF1-
070823-001
Using the XSCF Web, when you selected SSH
on the snapshot screen, the maximum number
of character input for Host, Directory, ID, and
Password doesn't correspond to the maximum
number of character input on the XSCF Shell.
To specify the value which exceeds the
maximum number of character input for the
XSCF Web, use XSCF Shell.
RTIF1-
070823-002
When you display the Logical tree on the
XSCF Web, there may be multiple displays of
the same domain, depending on the domain
configuration.
On the Menu, select System Board
Configuration and refer to the domain
configuration from XSB Status (All). Or use the
showboards
(8) command to refer to the
domain configuration.
RTIF1-
070823-003
When you display the Logical tree on the
XSCF Web, the hardware configuration of CPU
or memory which assigned to the domain
appears differently from the actual domain
configuration.
On the Menu, select Device Status to refer to
the domain hardware configuration. Or use the
showdevices
(8) command to refer to the
domain hardware configuration.
RTIF1-
070824-001
When remote power control mode of
interlocking mechanism for power supply to
domain, is enabled, after XSCF Unit is
replaced, the interlocking for power supply by
RCI cannot work.
After XSCF Unit is replaced, configures the
RCI again and sets the remote power control
mode.
RTIF1-
070824-002
On the XSCF Web, when you select Domain
Mode Configuration to perform various
settings, the pop-up screen may not appear but
"Undefined" may be displayed on the screen.
Select Domain Mode Configuration one more
time and perform the settings. Or once
terminate the XSCF Web and then perform the
settings.
RTIF1-
070824-003
On the XSCF Web, while the XCP import is in
process from the Firmware Update screen,
when you execute the REFRESH button, the
pop-up of "Uploading Now!" disappears and
the XCP import terminates abnormally.
None available at this time.
RTIF1-
070824-004
On the XSCF Web, on the Domain Status
screen, when you select an XSB displayed on
the Domain Component List, and in case the
selected XSB is not yet mounted or is Uni-XSB,
the pop-up screen displays no data.
None available at this time.
TABLE 6
XCP Issues Fixed in Releases Earlier Than XCP 1092
(Continued)
ID
Description
Workaround
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 8: ...viii SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...
Page 12: ...xii SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...
Page 88: ...76 SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...