Information About Software
51
6466617
Performing a hot plug operation with the PCI-
Express slot too quickly interrupts a PCI leaf
reset and occurs the following error:
cfgadm: Component system is busy
error
Pause a few seconds between the issue of each
cfgadm -c
command.
6481002
Installing the Solaris OS from the network
using certain PCI-Express cards may cause a
panic.
If you are using a Sun PCI-E Dual Gigabit
Ethernet Adapter MMF card or a Sun PCI-E
Dual Gigabit Ethernet Adapter UTP card, do
not install the Solaris using either of these
cards. Instead, use other network devices, such
as the onboard Gigabit Ethernet or another
network device.
6515648
"Replumb Failed
" error appears when
dr@0:SB1::memory
fails.
Once the DR operation is complete, it can be
plumbed up manually.
Example steps to re-plumb the interface
manually:
# ifconfig
interface
plumb
xxx.xxx.xxx.xxx
n bro up
# ifconfig
interface
group
group-name
# ifconfig
interface
addif
xxx.xxx.xxx.xxx
-failover deprecated up
This workaround assumes that the
/etc/hostname.
interface
file is correctly
configured for the IPMP group and does not
need any modification. The IP addresses used
in the example above should match what was
previously used and what matches the
/etc/hostname.<
interface
> file
.
6516135
Ap_Id format and devices may not be shown
correctly by
cfgadm
(1M).
Use the following operations to display all of
the PCI slots.
1)
devfsadm
(at Solaris prompt)
2)
cfgadm
6519290
Large amounts of I/O on swap devices can
cause the system to appear hung by
overwhelming the I/O system. The amount of
I/O required can be generated through a
number of ways, eg memory shortage, heavy
use of
/tmp
etc.
Set the following to
/etc/system
and then
reboot the domain:
set maxfastscan=0x2000
TABLE 7
Solaris OS Issues and Workarounds for All Supported Releases
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 8: ...viii SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...
Page 12: ...xii SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...
Page 88: ...76 SPARC Enterprise M8000 M9000 Servers Product Notes for XCP Version 1092 April 2010 ...