Information About Software
73
Identifying Degraded Memory in a
System
1. Log in to XSCF.
2. Type the following command:
The following example identifies that DIMM number 00A on CMU#3 has degraded
memory.
Identifying Different Memory Sizes in a
System Board
To identify if the domain contains system boards with different memory sizes, you
can use either of the following commands to display the list of memory sizes:
■
showdevices
(8) command on the XSCF
■
prtdiag
(1M) command on the domain
Using the
showdevices
Command
1. Log in to XSCF.
XSCF>
showstatus
XSCF>
showstatus
CMU#3 Status:Normal;
* MEM#00A Status:Degraded;
Summary of Contents for SPARC Enterprise M8000